Bypass Valves

Model B166B Automatic, Dual-Purpose Bypass Valve

The model B166B is a combination bypass and priming valve designed specifically for small cylinder filling pumps such as Corken’s Coro-Flo® regenerative turbine and side channel pumps. The patented vapor elimination system improves the pumping efficiency and minimizes wear by keeping the pump consistently primed. It is a smooth operating bypass with moderate to high pressure build-up and is available in 3/4″ and 1″ sizes.

Typical Applications: Ideal for small cylinder filling pumps and aerosol propellant feed pumps.

  • Connections: 3/4” or 1” inlet & outlet
  • Differential pressure range: 25 – 225 psi (1.7 – 15.5 bar)
  • Maximum working pressure: 400 psig (27.6 bar g)
  • Capacity: 40 gpm (151 l/min)

B177 Differential Bypass Valve

The model B177 is low-pressure build-up bypass valve designed for applications that require protection for positive displacement pumps. It is ideal for capacities ranging from 100 to 350 gpm (22.7 to 79.5 m3/hr). It can also be used as a differential back-pressure valve that assures adequate pressure on meters. To function properly, this valve requires a pressure sensing line from the storage tank. Available in 2″ and 2-1/2″ sizes.

Typical Application: Used in liquefied gas bulk-plant installations utilizing loading and unloading pumps.

  • Connections: 2” or 2-1/2” inlet/outlet
  • Differential pressure range: 10 – 125 psi (.7 – 8.6 bar)
  • Maximum working pressure: 400 psig (27.6 bar g)
  • Capacities up to 390 gpm (1,476 l/min)
  • NPT or weld neck

Model ZV200 Bypass Valve

The model ZV200 is a 2″, low-pressure build-up bypass valve designed for applications that require protection for positive displacement pumps. It is ideal for capacities up to 250 gpm (56.8 m3/hr). The model ZV200 has a continuous internal bleed that helps operate systems containing an “air” or “electric” operated internal valve.

Typical applications: Used for truck and stationary applications utilizing medium to large capacity loading and unloading pumps.

  • Connections: 1.25″, 1.5″, 2″, & 2.5″ inlet & outlet
  • Differential pressure range: 41 – 150 psi (2.8 – 10.3 bar)
  • Maximum working pressure: 400 psig (27.6 bar g)
  • Capacity: 180 gpm (681 l/min) @ 70 psi (4.82 bar) of differential pressure
  • Capacity: 250 gpm (946 l/min) @ 120 psi (8.27 bar) of differential pressure
  • NPT or weld neck
Category:

The model B166B is a combination bypass and priming valve designed specifically for small cylinder filling pumps such as Corken’s Coro-Flo® regenerative turbine and side channel pumps. The patented vapor elimination system improves the pumping efficiency and minimizes wear by keeping the pump consistently primed. It is a smooth operating bypass with moderate to high pressure build-up and is available in 3/4″ and 1″ sizes.

Product Description

The model B166B is a combination bypass and priming valve designed specifically for small cylinder filling pumps such as Corken’s Coro-Flo® regenerative turbine and side channel pumps. The patented vapor elimination system improves the pumping efficiency and minimizes wear by keeping the pump consistently primed. It is a smooth operating bypass with moderate to high pressure build-up and is available in 3/4″ and 1″ sizes.

Brand

Corken

Corken is recognized as a global leader in the manufacture of industrial compressors, pumps and accessories for flammable, volatile, and toxic liquids and gases. Their exceptional reputation in the process, energy and transportation industries is built upon decades of maintaining the highest quality products and customer service standards. This, combined with an absolute dedication to product performance, is what makes Corken recognized worldwide for its manufacturing leadership.

Reviews

There are no reviews yet.

Be the first to review “Bypass Valves”